This Small Vessel Myograph recording system consists of the following equipments:
Specifications / Technical Data
Every part of the mechanical assembly is made of stainless steel. The basement of the organ bath is a strong fixing plate standing on three feet. In the middle of the basement there is a heated tissue chamber. The material of the heated chamber is a very special kind of steel alloy, which is fully compatible with the living tissues. The temperature of the heated chamber (organ bath) is regulated with the accuracy of better than 0.5 Centigrade.
Small pieces of vessels can be fixed as rings on two tungsten wires. The internal diameter range of the measurable vessels is 1 to 10 mm. One of the fixing wires is attached to the force sensor. The other, opposite holding wire is fixed on the removable upper part on easily adjustable way. The force sensor shall be fine-positioned by a micrometer, to provide accurate control of vessel circumference.
The whole measuring unit, including the force sensor, and the opposite holding wire can be removed from the basement in one piece completely. This feature provides a comfortable and precise way to fix the examined tissue on the wires. The removable design of the measuring unit helps positioning of the vessel or tissue on the fixing wires accurately.
There are flexibly adjustable tubes to transport carbogene gas and saline solution into the tissue (organ) bath to maintain the optimal physiological conditions for the tissue. The solution and gas tubes are easily detachable and repositionable on the basement.
Scope of delivery:
This Small Vessel Myograph recording system consists of the following equipments:
Specifications / Technical Data
Every part of the mechanical assembly is made of stainless steel. The basement of the organ bath is a strong fixing plate standing on three feet. In the middle of the basement there is a heated tissue chamber. The material of the heated chamber is a very special kind of steel alloy, which is fully compatible with the living tissues. The temperature of the heated chamber (organ bath) is regulated with the accuracy of better than 0.5 Centigrade.
Small pieces of vessels can be fixed as rings on two tungsten wires. The internal diameter range of the measurable vessels is 1 to 10 mm. One of the fixing wires is attached to the force sensor. The other, opposite holding wire is fixed on the removable upper part on easily adjustable way. The force sensor shall be fine-positioned by a micrometer, to provide accurate control of vessel circumference.
The whole measuring unit, including the force sensor, and the opposite holding wire can be removed from the basement in one piece completely. This feature provides a comfortable and precise way to fix the examined tissue on the wires. The removable design of the measuring unit helps positioning of the vessel or tissue on the fixing wires accurately.
There are flexibly adjustable tubes to transport carbogene gas and saline solution into the tissue (organ) bath to maintain the optimal physiological conditions for the tissue. The solution and gas tubes are easily detachable and repositionable on the basement.
Scope of delivery:
Do you have comments? Please to post comments here!